Home » Lab Equipment Supplies » » Large Laboratory Sterilizers (69 Large Capacity Series) - 840 Liters

Large Laboratory Sterilizers (69 Large Capacity Series) - 840 Liters

Item# 05196TUT

The 69 autoclave series is designed to cover a large range of applications for laboratories, research institutes and biotechnology facilities.  The autoclave series has a chamber volume ranging in size from 510 to 1010 liters.

  • Chamber Dimensions (610W x 910H x 1515D) 
  • Chamber Volume in Liters (840)

Features:

  • The autoclave operates with saturated steam as the sterilizing agent with a temperature range from 105 °C (221°F) to 137 °C (279 °F) and a working pressure that meets AMSE and PED requirements.
  • Each autoclave model is available with either single or double door.
  • The 69 series is available with two door options:
  • Fully automatic horizontal sliding door
  • Hinged door with automatic locking
  • Tuttnauer laboratory autoclaves are designed to meet BL3 and BL4 bio-safety levels. 
  • Furthermore, an optional Bio-Hazard system allows for an effluent decontamination cycle that sterilizes contaminated laboratory waste. 
  • Our quality features enable the convenience and durability needed to operate an autoclave with complete peace of mind.
  • The fully jacketed chamber is constructed of long lasting 316L grade stainless steel with superior corrosion resistance.
  • In addition, the generator and piping are constructed of stainless steel.
  • The pneumatic valves are air pressure operated, reducing maintenance.
  • They are safer and more reliable, eliminating the requirement for high voltage.
  • In addition, if no buttons or switches are operated for four hours, the autoclave will switch to standby mode.

Door Safety

  • The doors are designed with independent mechanical and digital safety features that guarantee a safe working of the sterilizer.
  • A safety device prevents the operator from opening the door when chamber is pressurized
  • Steam is not allowed into the chamber when the door is open
  • A cycle will not start if the door is open or not properly closed
  • The door cannot open until chamber pressure reaches room pressure
  • Sliding Door Safety -The sliding door progress will automatically stop if an obstruction is detected
  • Double Door Safety – interlocks prevent both doors from being opened simultaneously  

General Safety Features:

  • Double Independent Monitoring: The combined digital and mechanical monitoring provides a cross reference and guarantees accurate results.
  • The operator has two independent means to monitor temperature and pressure.
  • Safety Valves: Both the chamber and the jacket are equipped with safety valves –if the pressure exceeds the allowed limit the safety valves will discharge.
  • Built-in Steam Generator Safety: A water level monitoring system maintains a constant water level and ensures safe operation of the heaters.
  • Emergency Shut-Off: Easily accessible emergency switches for immediate and safe shut down of the sterilizer. 

High Precision Documentation

  • Cycle documentation is crucial within the laboratory. A cycle that is not properly recorded is not considered done.
  • Tuttnauer uses an advanced microprocessor for the automated process control. 
  • Tuttnauer Control Panel is user-friendly, and consists of a 4 line, 20 Column LCD and a functional touchpad.
  • A self diagnostic system provides messages and alerts that are displayed in a clear language.
  • Audible alerts are sounded with the messages.
  • The LCD display provides constant cycle parameter readouts and cycle progress information.
  • The control system is self-diagnostic and provides fault messages to the operator.
  • Double door sterilizers may be installed with an optional control interface on the unloading side of the autoclave. 
  • If requested, a double door sterilizer may have a fully operated console on both sides. 
  • The modularity and flexibility of our system gives you targeted and customized solutions to further improve the tracking and documentation of the sterilization process.
  • The following documentation  features are optional.

Touch Screen

  • The touch screen in combination with ADMC-software displays cycle data in both a textual or graphical interface and provides a continuous visual guide of the progress of each stage in the sterilization cycle.
  • Moreover, it provides a visual display of all piping for monitoring purposes.

ADMC software

  • The ADMC software allows complete control and monitoring of up to eight sterilizers.
  • The software retrieves data, creates graphs, tables and print outs, controls the autoclave and shows real-time data.

Barcode Reader

  • The barcode reader allows material identification.
  • The data is transferred to the ADMC and linked to the sterilization cycle parameters for streamlined instrument handling.

Chart Recorder

  • The high speed chart recorder is an independent temperature and pressure measuring system.
  • It features analog/mechanical trend records and print-outs in color.
  • Simple operation with an easy-view display allows one to key-in various items of set data.

Data Logger

  • The data logger is the hospital’s protection, making documentation even more convenient and reliable.
  • It stores over 100,000 hours of cycle data, displayed either graphically or numerically.
Submit a Question:
Name:
Email:
Phone:

 Optional

Subject: Large Laboratory Sterilizers (69 Large Capacity Series) - 840 Liters, 05196TUT
Question: Limit 300 characters
Verification CAPTCHA image - Enter number in the space below
- Can't read it?

Disclaimer

Please limit your questions to medical equipment & supplies, only. For a medical diagnosis please consult with your physician. Although we try to respond to every inquiry, we reserve the right not to respond to inappropriate or unrelated questions.

Print this page
Astra 100-0115-92BEM
Unit: Single  QTY    Add to Cart
Your Price: Call For Pricing
1-877-706-4480


Request Volume Pricing
email to friend add to favorites Product in stock
Your Name:
Your Email:
Friend's Name:
Friend's Email:
Verification: CAPTCHA image
- Can't read it?
Message:
(max 150 characters)