Vertical Laboratory MLV Sterilizers Semi Automatic - 85 Liters
Item #: VLM-0783TUT
Tuttnauer MLV Laboratory line of semi automatic, electro-mechanically controlled, vertical steam sterilizers provides safe, economical and effective sterilization.
Chamber Dimensions 15" x 27.2"
Chamber Volume in Liters (85)
External Dimensions 25.6"W x 37.4"H x 19.7"D
Heating Performance in KW (6.0)
Voltage in Volt 50/60Hz (380-400)
Sterilization Applications:
- Liquids such as nutrient media and buffer solutions
- Solid items such as pipettes, tubes and filters
- Glassware and plastic articles
- Waste sterilization
- The various applications can be carried out using the autoclave’s standard programs.
- Additional options ensure more control overresults and optimal, safe and repeatable sterilization processes.
- For special applications, our experienced team will customize a suitable method for you.
Sterilizer Features:
- The sterilizer microcomputer control system provides high reliability and safe operation.
- 6 individual preset programs.
- LCD Displays pressure, temperature, time and alerts.
- Pre-selected parameters remain programmed until altered.
- Sterilization Initiation - the PT-100 temperature sensor in reference vessel ensures that the set sterilization temperature is actually attained when sterilization starts.
- Demineralized water level for steam generation is automatically regulated.
- Exhaust steam is cooled down before leaving the autoclave.
- Heat-resistant plastic covering on lid prevents contact with hot parts and protects from burning.
- Temperature and pressure regulation
- Pre-prepared for cooling - The autoclaves are prepared for the retrospective fitting of cooling equipment; both electronics and cooling coils can be fitted without difficulty.
- Validation ports are available for external temperature sensors for validation and qualification purposes.
- RS 232 interface
Safety Features:
- Pressure-activated door lock prevents the door from opening under pressure.
- Temperature-dependent door lock - the system prevents the door from opening until the temperature drops below a specified level, thereby preventing delayed boiling
- Door lock safety switch prevents the sterilization program from being started if the door has not been closed properly
- Water level safety device prevents the autoclave from being heated up in the case of insufficient water
- Excess temperature safety device switches off the heating elements if too high a temperature is attained.
- Overpressure valve releases over pressure in order to prevent high pressure risk.
Loading Capacity:
Erlenmeyer flasks:
- 250ml - 4 x 12
- 500ml - 3 x 7
- 1000ml - 2 x 4
- 2000ml - 2 x 3
- 3000ml - 2 x 2
- 5000ml - 1
Schott-Duran flasks:
- 250ml - 4 x 18
- 500ml - 3 x 11
- 1000ml - 2 x 8
- 2000ml - 2 x 4
- 5000ml - 2
- 10000ml - 1
|