Large Laboratory Sterilizers (69 Large Capacity Series) - 680 Liters

Item #: 02196TUT

The 69 autoclave series is designed to cover a large range of applications for laboratories, research institutes and biotechnology facilities.  The autoclave series has a chamber volume ranging in size from 510 to 1010 liters.

  • Chamber Dimensions (610W x 910H x 1215D) 
  • Chamber Volume in Liters (680)

Features:

  • The autoclave operates with saturated steam as the sterilizing agent with a temperature range from 105 °C (221°F) to 137 °C (279 °F) and a working pressure that meets AMSE and PED requirements.
  • Each autoclave model is available with either single or double door.
  • The 69 series is available with two door options:
  • Fully automatic horizontal sliding door
  • Hinged door with automatic locking
  • The laboratory autoclaves are designed to meet BL3 and BL4 bio-safety levels. 
  • Furthermore, an optional Bio-Hazard system allows for an effluent decontamination cycle that sterilizes contaminated laboratory waste. 
  • Our quality features enable the convenience and durability needed to operate an autoclave with complete peace of mind.
  • The fully jacketed chamber is constructed of long lasting 316L grade stainless steel with superior corrosion resistance.
  • In addition, the generator and piping are constructed of stainless steel.
  • The pneumatic valves are air pressure operated, reducing maintenance.
  • They are safer and more reliable, eliminating the requirement for high voltage.
  • In addition, if no buttons or switches are operated for four hours, the autoclave will switch to standby mode.

Door Safety

  • The doors are designed with independent mechanical and digital safety features that guarantee a safe working of the sterilizer.
  • A safety device prevents the operator from opening the door when chamber is pressurized
  • Steam is not allowed into the chamber when the door is open
  • A cycle will not start if the door is open or not properly closed
  • The door cannot open until chamber pressure reaches room pressure
  • Sliding Door Safety -The sliding door progress will automatically stop if an obstruction is detected
  • Double Door Safety – interlocks prevent both doors from being opened simultaneously  

General Safety Features:

  • Double Independent Monitoring: The combined digital and mechanical monitoring provides a cross reference and guarantees accurate results.
  • The operator has two independent means to monitor temperature and pressure.
  • Safety Valves: Both the chamber and the jacket are equipped with safety valves –if the pressure exceeds the allowed limit the safety valves will discharge.
  • Built-in Steam Generator Safety: A water level monitoring system maintains a constant water level and ensures safe operation of the heaters.
  • Emergency Shut-Off: Easily accessible emergency switches for immediate and safe shut down of the sterilizer. 

High Precision Documentation

  • Cycle documentation is crucial within the laboratory. A cycle that is not properly recorded is not considered done.
  • Tuttnauer uses an advanced microprocessor for the automated process control. 
  • Tuttnauer Control Panel is user-friendly, and consists of a 4 line, 20 Column LCD and a functional touchpad.
  • A self diagnostic system provides messages and alerts that are displayed in a clear language.
  • Audible alerts are sounded with the messages.
  • The LCD display provides constant cycle parameter readouts and cycle progress information.
  • The control system is self-diagnostic and provides fault messages to the operator.
  • Double door sterilizers may be installed with an optional control interface on the unloading side of the autoclave. 
  • If requested, a double door sterilizer may have a fully operated console on both sides. 
  • The modularity and flexibility of our system gives you targeted and customized solutions to further improve the tracking and documentation of the sterilization process.
  • The following documentation  features are optional.

Touch Screen

  • The touch screen in combination with ADMC-software displays cycle data in both a textual or graphical interface and provides a continuous visual guide of the progress of each stage in the sterilization cycle.
  • Moreover, it provides a visual display of all piping for monitoring purposes.

ADMC software

  • The ADMC software allows complete control and monitoring of up to eight sterilizers.
  • The software retrieves data, creates graphs, tables and print outs, controls the autoclave and shows real-time data.

Barcode Reader

  • The barcode reader allows material identification.
  • The data is transferred to the ADMC and linked to the sterilization cycle parameters for streamlined instrument handling.

Chart Recorder

  • The high speed chart recorder is an independent temperature and pressure measuring system.
  • It features analog/mechanical trend records and print-outs in color.
  • Simple operation with an easy-view display allows one to key-in various items of set data.

Data Logger

  • The data logger is the hospital’s protection, making documentation even more convenient and reliable.
  • It stores over 100,000 hours of cycle data, displayed either graphically or numerically.